Foss
Kjeltec™ 8100 - semi-automatic distillation unit
The Kjeltec™ 8100 distillation unit provides a simple and reliable solution for safe, semi-automatic distillations.
Features:
- Automatic dilution, alkali addition, distillation and tube emptying provide ease of use
- Variable output steam generator broadens application area to other volatile components
- Official and accurate procedures (ISO, AOAC, EPA, DIN) simplify validation
- Patented SAfE feature for safe distillation of tubes with salt cakes
- Built-in safety systems for user protection
- Self adjusting cooling water control saves water and reduces costs
- Bellows pumps for accurate dispensing of reagents
- Alkali resistant plastic splash head & tube emptying vessel for long lifetime
Specifications
Sample: | Food and feed |
Parameters: | Kjeldahl nitrogen/protein, ammonium, TKN, etc. |
Analysis time: | 3.5 minutes at 30 mg N/6.5 minutes at 200 mg N |
Distillation capacity: | ~ 40 ml/min |
Measuring range: | 0.1 – 200 mg N |
Colorimetric titration system: | not possible |
Autosampler: | not possible |
Kjeltec™ 8200 - automatic distillation unit
The Kjeltec™ 8200 Auto Distillation unit is the ultimate solution for safe, automatic distillation.
Features:
- All the features of the Kjeltec 8100 plus:
- Receiver solution addition
- Automatic safety door
- External titration connection (Mettler, Metrohm, Schott, etc.)
- Modularly upgradeable to analyser and sampler system
Specifikations
Sample: | Food and feed |
Parameters: | Kjeldahl nitrogen/protein, ammonium, TKN, etc. |
Analysis time: | 3.5 minutes at 30 mg N/6.5 minutes at 200 mg N |
Distillation capacity: | ~ 40 ml/min |
Measuring range: | 0.1 – 200 mg N |
Colorimetric titration system: | upgradeable |
Autosampler: | upgradeable |
Kjeltec™ 8400 - fully automatic distillation unit
A fully automated analyser, Kjeltec™ 8400, with on board self cleaning colorimetric titration system completes the range. Features:
- All the features of the Kjeltec 8200 plus:
- Titration, calculation and reporting
- Upgradeable to 20 or 60 place auto sampler for fully unattended operation
- Interchangeable burette for easy titrant exchange
- Ethernet connection eliminates communication problems with printers and balances
- Touch sensitive colour display
- Complete PC control of all registration and reporting through optional data management software Compass
Specifications
Sample: | Food and feed |
Parameters: | Kjeldahl nitrogen/protein, ammonium, TKN, etc. |
Analysis time: | 3.5 minutes at 30 mg N/6.5 minutes at 200 mg N |
Distillation capacity: | ~ 40 ml/min |
Measuring range: | 0.1 – 200 mg N |
Colorimetric titration system: | include |
Autosampler: | optional |
]
KT 200 Kjeltec™ - semi-automatic distillation unit
The KT 200 Kjeltec™ distillation unit provides a simple and reliable solution for safe and semi-automatic distillation. The possibility to pre-program alkali addition and distillation time supports the production of accurate results independent of operator. Accurate bellows pumps give long term stability in reagent delivery.
Specifications
Sample: | Food and feed |
Parameters: | Nitrogen, protein |
Analysis time: | 4 minutes at 30 mg N/7 minutes at 200 mg N |
Distillation capacity: | ~ 30 ml/min |
Measuring range: | 0.1 – 200 mg N |
Colorimetric titration system: | not possible |
Autosampler: | not possible |